Covair Structures Ltd

Highcroft, Coldharbour Lane, Bletchingley, Surrey. RH1 4NA. UK

Tel: 0870 7744555

Fax: 0870 0116766

E-Mail: johnwright@covairdomes.co.uk, helenwright@covairdomes.co.uk  

Tennis DomesPool DomesPicture GallerySizes and PricesEmergency ProceduresDouble-SkinContact Us

 

Benefits

 

Planning Consent

 

Dome Construction

 

Inflation & Access

 

Heating & Lighting

 

Usage and Life

 

Installation

 

Dismantling

 

Operation & Safety

 

Repairs Procedure

 

 

Dome Inflation Equipment

 

Two 12" diameter centrifugal fans with 1 hp motors are provided (see left image below), each with a starting load of 15 amps and a running load of 12 amps. One fan is sufficient to maintain the integrity of the dome during normal operating conditions, the second fan is connected to a wind speed sensor (anemometer) to switch it on in high wind conditions. Cost of electricity consumption, £8-£10 per week.

An optional self start generator is available to ensure the domes safety in the event of a power failure.

 

Dome inflation fans                                             Dome revolving door

 

Dome Access

 

Access is via a self supporting revolving door (see right image above) which minimises air escape thus maintaining the internal positive pressure.

 

Outward opening door

 

Disabled / Emergency Door

 

If required, a steel 1m x 2m outward opening door can be fitted at extra cost (above picture). This is useful where wheelchair access is required, or when regular furniture or gym equipment movement is needed.

 

 